Comparison of 5Kw Heat Pumps
This is a comparison table of all 2024-2025 heat-pump datasheet figures for make+models I am aware of.
Criteria:
- Target property 4-5Kw
- EN 14511/14825 (?) Average Climate and Low temperature = 35C and Medium = 55C
- Ordered by SCOP where higher is better. Where order is ambiguous the SCOP at 45C is used, and then 35C i.e. We prefer mild weather performance which gives greater yearly SCOP.
All SCOP figures are now correlated (i.e. replaced) with MCS 3rd party certified figures where possible. Please be aware currently indicates a device that has not got a verified performance and may not be correctly ranked among others.
Make/Model | SCOP@35C | SCOP@45C | SCOP@55C | Gas | Comment/Validation | Date Valid | Site/Datasheet |
---|---|---|---|---|---|---|---|
1 | 3 | 2 | |||||
Lambda 8Kw |
5.66 | 5.07 |
4.48 | R290 | No MCS cert as of 2024-06 | 2024-01 | site datasheet |
Ovum AC208P |
5.53 | 4.89 |
4.00 | R290 | No MCS cert as of 2024-06 | 2024-02 | site datasheet |
LG Therma V 9Kw |
5.23 | 4.49 |
3.75 | R290 | HM093HFX not on MCS? | 2024-01 | datasheet |
EBac H1A05WG-GB 5Kw | 4.91 | 4.38 | 3.96 | R32 |
MCS HP0369/01
|
2024-02 | site datasheet brochure |
Nibe 6kw | 4.87 | 4.07 | 3.46 | R32 |
MCS 012-C700141 over Datasheet(5.08,4.33 ,3.58) |
{todo} | datasheet |
Samsung Gen7 5Kw | 4.84 | 4.14 | 3.43 | R290 |
MCS 011-1W0686_2
|
{todo} | datasheet |
Aira 6KW 1.0 | 4.62 | 4.10 | 3.58 | R290 |
Source MCS HP0372/06
|
2024-03 | datasheet |
Bosch 5800i 5Kw | 4.65 | 4.08 |
3.50 | R290 |
5800iAW 5 OR-s not on MCS? Data source!? |
{todo} | site |
Baxi 5Kw | 4.77 | 4.06 | 3.39 | R32 |
MCS HP0033/10
|
{todo} | site |
Viessmann 151.A06 | 4.53 | 4.03 | 3.61 | R290 |
MCS 011-1W0590_06 over Datasheet(4.58,4.10 ,3.61) |
{todo} | datasheet |
Mitsubishi Ecodan | 4.42 | 3.90 | 3.53 | R290 |
MCS 037-0135-23-1 over Datasheet(4.62,4.08 ,3.53) |
{todo} | site |
Ideal 5Kw | 4.39 | 3.83 | 3.06 | R32 |
MCS KIWA 00027/023 HP over Datasheet(5.07,4.36 ,3.65) |
2023-06 | site |
Vaillant aroTherm+ 5Kw | 4.48 | 3.77 | 3.06 | R290 |
KIWA 00016/018HP
|
{todo} | datasheet |
Daikin Altherma 4Kw | 4.43 | 3.72 | 3.20 | R32 |
MCS 011-1W0527_3 over Datasheet(4.48,3.87 ,3.26) |
{todo} | site |
Octopus Cosy 6 | 3.98 | 3.36 | 3.06 | R290 |
MCS HP0255/03
|
2024-05 | TBD: MCS database source https://mcscertified.com/product-directory/ |
1
Make/Model
= models may cycle due to being oversized i.e. 8KW+2 = Datasheet-matches-MCS, = MCS-only-or-close-match, = MCS-not-close-to-datasheet, = Not validated/Unknown
3
1.23
= SCOP at 45C calculated as MEAN(35,55) when not made available in datasheet. This produces conservative underestimate of SCOP when unavailable.
Changes:
- Fix data-entry error on Ebac 45C 4.63 to 4.38 (down to 4th)
- 2024-02 Ovum AC208P from
5.78
to5.53
@ 35C,4.15
to4.00
@ 55C etc. old-datasheet - 2024-02 EBac H1A05WG-GB from
5.11
to4.91
@ 35C,4.12
to3.96
@ 55C old-datasheet - 2024-04-25 Added
Aira 6KW 1.0
with SCOP figures from MCS Product Database - 2024-06-03 Added
Octopus Cosy 6
with SCOP figures from MCS Product Database - 2024-06-10 Remove inconsistent standard in favour of 3rd party MCS correlation for SCOP accuracy, devices re-ordered respectively