This is the 2026 refresh of the heat-pump SCOP comparison. The current focus is the 5–6kW range (suitable for a well-insulated ~4–5kW-demand property), but the table is now a single filterable master table driven from a shared dataset, so larger outputs can be added over time — use the search box and the kW column to filter/sort.

The data now lives in _data/heat_pumps.yml as a clean single source of truth, so figures can be de-duplicated, re-ranked and checked by tooling rather than hand-edited in the table.

Criteria / methodology (unchanged from the 2024 table):

  • Target property demand ~4–5kW; units may cycle if oversized (8kW+).
  • EN 14511/14825 Average Climate. Low temp = 35°C, Medium = 45°C, High = 55°C.
  • Ordered by SCOP@35°C where higher is better; ambiguous ranks fall back to 45°C then 55°C (we prefer mild-weather performance which gives greater yearly SCOP).
  • MCS Product Database figures are the source of truth and replace datasheet figures where they differ — see MCS Product Directory.
  • Where a model has no MCS certification, published manufacturer/datasheet figures are used instead and flagged 💔 (unverified). Note many manufacturers publish only COP, not the SCOP@35/45/55 trio, so some newly launched models show no SCOP until they are MCS-certified.
  • A * on SCOP@45°C means it was estimated as mean(35,55) because the datasheet omitted it (a conservative underestimate).

Status column legend

Badge Meaning
💎 Datasheet matches MCS-verified figures
📗 MCS-only or a close match to datasheet
📘 MCS present but not close to datasheet (MCS used) — hover the ds≠ marker for datasheet claims
💔 Not validated / unknown — may be mis-ranked

MCS verified, Datasheet only and Rumoured / no data in the Status column are searchable terms — type one into the search box to isolate that confidence tier.

# Make/Model kW SCOP@35°C SCOP@45°C SCOP@55°C Gas Status MCS Cert. Sound Power (dBA) Wall Date Valid Links
1 Lambda 8kW 8 5.66 5.07* 4.48 R290 💔 Datasheet only 42-56 2024-12 site datasheet
2 Ovum AC208P 8 5.53 4.89* 4.0 R290 💔 Datasheet only 41-54.5 2024-07 site datasheet
3 LG ThermaV HM093HF 9kW 9 5.04 3.74 3.75 R290 📘 MCS verified ds≠ 011-1W0831_04 48-49 2024-01 site
4 EBac H1A05WG-GB 5kW 5 4.91 4.38 3.96 R32 💎 MCS verified HP0369/01 64.5 👍 2024-02 site
5 Nibe 6kW 6 4.87 4.07 3.46 R32 📘 MCS verified ds≠ 012-C700141 53 datasheet
6 Samsung Gen7 5kW 5 4.84 4.14 3.43 R290 💎 MCS verified 011-1W0686_2 55 datasheet
7 Baxi 5kW 5 4.77 4.06 3.39 R32 💎 MCS verified HP0033/10 58 site
8 Stiebel Eltron WPL-A 07 7 4.66 4.21 3.69 R454C 📘 MCS verified ds≠ 011-1W0393_02 48 2024 site datasheet
9 Aira 6kW 1.0 6 4.62 4.1 3.58 R290 📗 MCS verified HP0372/06 57 2024-03 datasheet
10 Bosch CS5800iAW 5kW 5 4.53 3.9 3.28 R290 📘 MCS verified ds≠ HP0329/06 42 site
11 Viessmann Vitocal 151.A06 6 4.53 4.03 3.61 R290 📗 MCS verified ds≠ 011-1W0590_06 51 👍 datasheet brochure
12 Vaillant aroTHERM plus 5kW 5 4.48 3.77 3.06 R290 💎 MCS verified KIWA 00016/018HP 51-55 👍 site datasheet
13 Daikin Altherma 4kW 4 4.43 3.72 3.2 R32 📗 MCS verified ds≠ 011-1W0527_3 60 ? site
14 Mitsubishi Ecodan R290 5 4.42 3.9 3.53 R290 📘 MCS verified ds≠ 037-0135-23-1 👍 site
15 Ideal Logic Air 5kW 5 4.39 3.83 3.06 R32 📘 MCS verified ds≠ KIWA 00027/023 HP 52 2023-06 site
16 Ecoforest ecoAIR+ 230 (6-24kW) 6 4.38 3.49 3.11 R290 📗 MCS verified 011-1W0921_6 2024-10 site
17 Octopus Cosy 6 6 3.98 3.36 3.06 R290 📗 MCS verified HP0255/03 53.8 2024-05 site MCS
Grant Aerona 290 (R290) 6 R290 💔 Rumoured / no data site datasheet
Panasonic Aquarea R290 (5kW) 5 R290 💔 Rumoured / no data site
Warmflow Zeno R290 6 R290 💔 Rumoured / no data site
CTC Ecoair 700M 7 R290 💔 Rumoured / no data 46 ? 2024-03 site
Wondrwall DR-HP-006-UK 6 R290 💔 Rumoured / no data 60 ? 2024-03 site datasheet

Notes:

  • Figures are refreshed from the MCS Product Database using tools/fetch_mcs.py; links are validated with tools/check_links.py (see tools/README.md).
  • The older 2024 5kW table is retained for history.

ToDo / research backlog:

  • Vaillant aroTHERM plus 2025/26 (improved-spec model expected to reach the UK market in 2026).
  • Confirm SCOP + MCS certs for newly announced 2025/26 models and move them from Rumoured / no data up into a verified tier as figures are published.